Search Results/Filters    

Filters

Year

Banks



Expert Group










Full-Text


Issue Info: 
  • Year: 

    2016
  • Volume: 

    34
  • Issue: 

    398
  • Pages: 

    1060-1065
Measures: 
  • Citations: 

    0
  • Views: 

    839
  • Downloads: 

    0
Abstract: 

Background: Multislice computed tomography (CT) angiography is a robust imaging method for noninvasive assessment of coronary artery diseases، which is associated with high radiation dose. Having knowledge of the various parameters used to estimate the dose plays an important role in increasing the understanding of dose delivered to patients and help operators and technologist to reduce the dose. In this research، the amounts of Weighted computed tomography Dose Index (CTDIW) for coronary CT angiography exams were measured in Isfahan city, IranMethods: To calculate the dose، an ionization chamber (Piranha، X-ray Analyzer، RTI Electronics and Sweden) and acrylic body phantom were used. Common conditions of coronary CT angiography used in two centers were applied for this project. Finally, CTDIW of all the scans were calculated using the related formulation.Findings: The amount of mean CTDIW for calcium score exams in Sina and Alzahra hospitals were 0.468±0.190 and 2.354±0.610 mGy, respectively (P = 0.007); and for coronary CT angiography scans in Sina and Alzahra hospitals were 6.221±1.290 and 5.299±0.840 mGy, respectively (P=0.860).Conclusion: CTDIW for the calcium score was significantly different in the two centers، but there was not significant difference in the two centers for coronary CT angiography scans. In this study، the amount of CTDIW was much lower than the measured in other centers. Since scan parameters have an important effect on the dose value، training and precision of technologist result in dose reduction and patient radiation protection.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 839

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 3
Issue Info: 
  • Year: 

    2013
  • Volume: 

    12
  • Issue: 

    4 (85)
  • Pages: 

    419-428
Measures: 
  • Citations: 

    0
  • Views: 

    926
  • Downloads: 

    0
Abstract: 

Background and Objective: The aim of this study was to evaluate the diagnostic ability of CBCT to detect external root resorption.Subjects and Methods: External root resorption defects of different sizes and in different locations were simulated in 60 human mandibular incisors. Cavities simulating root resorption defects of small size (0.3´0.6 mm), medium (1.2´0.6 mm) and large (1.8´0.9 mm) were drilled in the cervical, medial and apical thirds of buccal surfaces. The teeth were divided in random groups and mounted in the mixture of acryle and dryed skull sheep powder. CBCT scan was used to evaluate external root resorption in 180 root thirds by two blinded observer. Statistical analysis was done with Kappa test.Results: Sensitivity of CBCT to detect external root resorption was 89% and the specificity was 99 %.The most defects that was detected were on the medial root thirds and the lowest defects that were detected were on the apical root. The percentage of small defects detection was 80%.Conclusion: CBCT technique is a very good method to evaluate external root resorption with high sensitivity and excellent specificity. It can detect the defects as small as 0.3mm.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 926

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    1395
  • Volume: 

    17
Measures: 
  • Views: 

    289
  • Downloads: 

    0
Keywords: 
Abstract: 

لطفا برای مشاهده چکیده به متن کامل (PDF) مراجعه فرمایید.

Yearly Impact:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 289

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0
Issue Info: 
  • Year: 

    2019
  • Volume: 

    21
  • Issue: 

    1
  • Pages: 

    338-344
Measures: 
  • Citations: 

    0
  • Views: 

    399
  • Downloads: 

    0
Abstract: 

BACKGROUND AND OBJECTIVE: Having the correct anatomical points and the size of the pedicle dimension is necessary to minimize neurological complications. Currently, the gold standard for spinal fusion is the use of pedicle screws. In this method, the pedicle screw should be placed in its ideal position. Given the importance of this topic, the present study was performed to determine the dimensions of right and left pedicle by computed tomography (CT) scan in three axial, coronal and sagittal planes based on gender in Fars-native ethnic group. METHODS: This cross-sectional study was performed on 40 patients (20 females and 20 males aged 18 – 45 years) from Fars-native ethnic group. The average height for males was 165 to 180 cm and for females between 165 and 175 cm. Healthy vertebrae were selected in people who referred to a CT scan unit with symptoms of spinal pain or trauma. Determination of height, length and width of right and left pedicle of lumbar vertebrae in axial, coronal and sagittal view in 1. 5 mm sections was performed by CT scan. FINDINGS: Mean and standard deviation of height (1. 458± 0. 141), width (0. 788± 0. 173), and length (1. 248± 0. 195) of pedicle in men (based on millimeter) was significantly higher compared to mean and standard deviation of height (1. 268± 0. 140), width (0. 618± 0. 148), and length (1. 08± 0. 174) in women (p<0. 05). CONCLUSION: The results of this study showed that gender affects the dimensions of lumbar vertebral pedicle.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 399

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2022
  • Volume: 

    18
  • Issue: 

    1
  • Pages: 

    98-106
Measures: 
  • Citations: 

    0
  • Views: 

    276
  • Downloads: 

    0
Abstract: 

Introduction: The inferior alveolar canal is an important anatomical structure in the field of dentistry implants and cone beam computed tomography (CBCT) is an important diagnostic technique. The aim of this study was to evaluate the prevalence of anatomical variations of the mandibular canal observed in CBCT images. Materials & Methods: In this descriptive-analytic study 384 inferior alveolar canals were evaluated in 192 patients, who were referred to the radiology department of Isfahan Azad University in 1396 for a cone-beam computed tomography. Radiographs were performed to assess the frequency of different left and right mandibular canal segregations by sex in terms of upper and lower position, baccolingual position, shape of the general canal. The frequency and different types of existing mandibular plug canals were also evaluated. Data were analyzed by Chi Square, independent T Test, paired t-test. (p value < 0. 05). Results: The mandibular canal was 2. 1% of the lower position, 11. 9% of the upper position and 86% of the middle position. Statistically significant differences were observed between the frequency distributions of canal positions and gender (p value = 0. 004). The prevalence of Bifid mandibular canals was 14. 8%. There was no significant relationship between the shape of the general channel path and gender. There was no significant difference between the mean distance between the mandibular canal and the buccal cortex in both Molar and Ramus with the sex of the subjects and the side of the canal (p value < 0. 05). Conclusion: The highest frequency of mandibular canal in most subjects was on the right in the intermediate position. The mean distance between mandibular canal and buccal cortex in Ramos and Molars area on both right and left sides was not significantly different between men and women.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 276

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2012
  • Volume: 

    19
  • Issue: 

    2 (SN 64)
  • Pages: 

    39-43
Measures: 
  • Citations: 

    0
  • Views: 

    1095
  • Downloads: 

    0
Abstract: 

Introduction & Objective: The mental foramen is a part of lower jaw which has neurovascular bundles and also is important in biology. 3D imaging of this area by cone beam computed tomography (CBCT) before surgery can prevent some problems. This study aims to evaluate the anatomic position and geometrical shape of the mental foramen by CBCT images.Materials & Methods: In this research, the CBCT images (by NewTom and Planmeca promax 3D set) of 85 patients referred to dentistry school clinic or other clinics in Hamadan city were studied. These patients did not have their first and second premolar teeth extracted in both right and left sides. The geometrical shape of mental foramen, the canal angle connecting to mental foramen compared to the buccal plate of lower jaw, distance from the lower border of mental foramen to the lower border of lower jaw, position of mental foramen relating to the root of adjacent tooth and the incidence of accessory mental foramen were studied.Results: The means of canal angle connecting to mental foramen in the right side in men and women were 123.3 and 130.1 and in the left side were 123.8 and 133.7, respectively. The mean distance from the lower border of mental foramen to the lower border of lower jaw in the right side in men and women were: 12.4 and 13.3 mm and in the left side were: 12.7 and 13.6 mm, respectively. Also, there is a meaningful statistical relation between gender and the angle of canal of mental foramen, regarding to the buccal plate in both sides.Conclusion: Regarding to the variations in the position and shape of mental foramen and the angle connecting to the mental foramen related to the buccal plate and accessory mental foramen, investigation of CBCT images before placement of implants is necessary.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 1095

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    1395
  • Volume: 

    17
Measures: 
  • Views: 

    389
  • Downloads: 

    0
Keywords: 
Abstract: 

لطفا برای مشاهده چکیده به متن کامل (PDF) مراجعه فرمایید.

Yearly Impact:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 389

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0
Issue Info: 
  • Year: 

    2015
  • Volume: 

    17
  • Issue: 

    3 (55)
  • Pages: 

    122-126
Measures: 
  • Citations: 

    0
  • Views: 

    747
  • Downloads: 

    0
Abstract: 

Background and Objective: Many surgeries are performed on anterior region of mandible. Incisive branch of the inferior alveolar nerve is located in the anterior region of mandible. The identification of various form of nerve is important for diagnosis and treatment plan. This study was carried out to the assessment of visibility and extension rate of incisive branch of the inferior alveolar nerve in cone beam computed tomography (CBCT) imagings.Methods: This descriptive- analytic study was performed on 105 CBCT images. The presences or absence of incisive branch of the inferior alveolar nerve and assessment of visibility and extension rate of mandibular incisive canal were studied.Results: In 79% extension of the incisive branch of the inferior alveolar nerve were observed. 18.07% of extensions were observed in one-side and 78.31% were bilateral. Extension of the incisive branch of the inferior alveolar nerve was observed to central, lateral and canine tooth in 59%, 26.5% and 14.5% respectively. There was no significant relation beween gender and age of subjects with extension of the incisive branch of the inferior alveolar nerve.Conclusion: Regarding the high visibility of the incisive nerve branches in the lower dental CBCT images this method can be used to evaluate the anterior region of mandible.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 747

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 1
Issue Info: 
  • Year: 

    0
  • Volume: 

    19
  • Issue: 

    3 (مسلسل 65)
  • Pages: 

    30-35
Measures: 
  • Citations: 

    0
  • Views: 

    722
  • Downloads: 

    0
Abstract: 

مقدمه و هدف: دندان های کانین ماگزیلا نقش مهمی در زیبایی و فانکشن دارند. درمان بیماران با کانین نهفته ماگزیلا نسبت به سایر بیماران ارتودنسی دشوارتر بوده و نیاز به صرف زمان بیشتری دارد. هدف از این مطالعه تعیین شاخص دشواری درمان ارتودنسی دندان کانین نهفته ماگزیلا در توموگرافی کامپیوتری با اشعه مخروطی ((CBCT بر اساس نظر متخصصین ارتودنسی می باشد.روش کار: در این مطالعه مقطعی، نه فاکتور موثر بر سختی درمان در 36 CBCT بیمار با 50 کانین نهفته با استفاده از برنامه Dolphin 3D اندازه گیری شد. نه تصویر به دست آمده از بیماران به همراه اندازه گیری های انجام شده بر روی وب سایت طراحی شده به این منظور قرار داده شد. از 10 ارتودنتیست خواسته شد که سختی رویش کانین نهفته را از 1 تا 10 درجه بندی کنند. همچنین از آنها خواسته شد که میزان تاثیر هر یک از متغیرها در درمان را نیز از 1 تا 5 ارزیابی کنند. رگرسیون خطی با اثرات تصادفی در مرحله اکتشافی و رگرسیون خطی ساده در مرحله ایجاد مدل مورد استفاده قرار گرفت.نتایج: میانگین سن بیماران 5.8±19.08 سال و میانگین تجربه کلینیکی متخصصین 12.02±22.7 سال بود. سه متغیر در مرحله اکتشافی و 2 متغیر در مرحله ایجاد مدل حذف شدند. فاصله عمودی تا پلن اکلوزال (P=0.000)، همپوشانی در نمای فرونتال (P=0.000)، زاویه با پلن اکلوزال (P=0.029)،(P=0.000) Dilaceration و چرخش(P=0.029)  رابطه معنی داری با شاخص دشواری درمان داشتند.نتیجه نهایی: سختی درمان کانین نهفته ماگزیلا می تواند به صورت کمی با اندازه گیری متغیرها از روی تصاویر CBCT اندازه گیری شود.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 722

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2013
  • Volume: 

    20
  • Issue: 

    3 (SN 69)
  • Pages: 

    201-206
Measures: 
  • Citations: 

    0
  • Views: 

    762
  • Downloads: 

    0
Abstract: 

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants.Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh sheep bone. The bone densities of implant recipient sites were determined by CBCT. The maximum insertion torque value of each implant was recorded and stability was measured by Osstell. Spearman’s correlation coefficient was used to evaluate the correlations among the variables.Results: The mean density value, insertion torque, and Osstell value were 1481.78±166.614, 74.69±16.33 and 73.78±4.025 N/cm2 respectively. Statistically no significant correlations were found among the variables.Conclusion: The bone quality evaluated by CBCT showed no correlation with the primary stability of the implants.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 762

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button